Ice Fog as a Means to Induce Uniform Ice Nucleation During Lyophilization (Peer Reviewed) - The authors describe a novel means to control ice nucleation using a sterile cryogenic ice fog that is appl

ADVERTISEMENT

Ice Fog as a Means to Induce Uniform Ice Nucleation During Lyophilization (Peer Reviewed)
The authors describe a novel means to control ice nucleation using a sterile cryogenic ice fog that is applicable to laboratory-, pilot-, and production-scale lyophilizers.


BioPharm International
Volume 25, Issue 1, pp. 33-38

RESULTS AND DISCUSSION

Creating and uniformly distributing cryogenic ice fog

A key challenge for the commercial implementation of the ice-fog technique has been the creation of an ice fog that is sufficiently dense and that can be efficiently distributed to reach all vials in a large-scale lyophilizer. Because of this low density, not enough fog was available for all vials. Also absent in previous tests was an efficient system to distribute the ice fog within the freezing chamber and drive it into the vials. The system used in the present study produced a very dense fog and also distributed the fog throughout the freezing chamber within a short time (i.e., less than a minute). It is also possible, through this design, to control the density of the ice fog.

Fog creation and distribution were aided by the ejector assembly. The ejector serves two purposes. First, it provides an extremely efficient means for quickly forming the ice fog. Second, the suitably sized ejector provides enough pumping capacity to circulate the ice fog throughout the freezing chamber rapidly. It is a significant advantage that the ejector can accomplish both of these functions without introducing any moving parts or other complicated mechanisms that would be difficult to steam or otherwise sterilize.

Achieving ice nucleation in all vials at desired temperature

Figures 3 and 4 show the temperature measurements obtained in control and ice fog experiments, respectively, as a function of time. Ice nucleation was indicated at the point when the temperature of a vial increased sharply. This result is due to release of the latent heat of fusion of the solution upon freezing.

For the control experiment, the first vial nucleated at a temperature of around –9 C and the last vial nucleated at around –18 C (see Figure 3). About 20 minutes separated these two occurrences, and the remainder of the vials nucleated at various times inbetween. This variation in ice nucleation time could increase in production-grade environments, where solutions may be supercooled further due to the absence of any particulates or impurities in the atmosphere.

Based on the data from control experiments, a trigger vial temperature of –6 C was selected as tg. The choice of this tg was conservative so that all vials were cooled below their freezing point. This choice was to ensure that absence of freezing was a result of supercooling only, and not because a vial was at a temperature above the freezing point. Sometimes uneven vial temperatures may occur in laboratory-scale lyophilizers because of nonuniform shelf cooling. In addition, the temperature probes, except the trigger vial probe, measured the outside vial temperatures which might not reflect the solution temperature inside the vial at all times. If all vials are cooled below their freezing point, ice fog can be introduced at a much higher temperature below 0 C.


Figure 4: Temperature measurements obtained in ice-fog experiments as a function of time.
Shelves were allowed to cool at a ramp rate of 0.5 C/min, and the temperature of the trigger vial was constantly monitored. When trigger vial temperature hit –6 C, the ice fog was introduced. As seen in Figure 4, all vials nucleated at the same instant following the introduction of ice fog. Both vial populations, pure water and glycine solution, nucleated at about the same time on ice-fog introduction, indicating the general applicability of this technique for all supercooled solutions.


blog comments powered by Disqus

ADVERTISEMENT

ADVERTISEMENT

UPS' Pain in the Supply Chain Results
September 23, 2014
Merck KGaA Announces Acquisition of Sigma-Aldrich for $17 Billion
September 22, 2014
Pandemic Vaccine Facility Dedicated in Texas
September 19, 2014
GSK Fined in China Bribery Scandal
September 19, 2014
Guideline Delineates How to Implement GS1 Standards to Support DSCSA
September 19, 2014
Author Guidelines
Source: BioPharm International,
Click here