Statistical Equivalence Testing for Assessing Bench-Scale Cleanability - The two-one-sided t-test compares the equivalency of two data sets. - BioPharm International

ADVERTISEMENT

Statistical Equivalence Testing for Assessing Bench-Scale Cleanability
The two-one-sided t-test compares the equivalency of two data sets.


BioPharm International
Volume 23, Issue 2

SETTING A NULL HYPOTHESIS AND EQUIVALENCY LIMITS




The null hypothesis (also referred to as the equivalence hypothesis) states that the means of the cleaning times of two products are different by an amount θ or larger:


Figure 2
in which θ is the equivalence limit and μa and μb are the means of the two groups. To test for equivalence, the 90% confidence intervals for the difference between two groups are constructed. The null hypothesis that the groups differ by at least θ is rejected if the limits of the interval fall outside the θ bounds. Conversely, comparability is demonstrated when the bounds of the 90% confidence interval of the mean difference fall entirely within the θ bounds, as shown in Figure 2.

Note that the confidence interval width increases with smaller sample sizes of collected data and with less variability within each data group. The specifics behind the sample size calculation are outside the scope of this article. Larger sample size, however, would naturally result in a narrower confidence interval of the mean difference and hence would make declaring comparability easier. Likewise, although equivalency does not explicitly compare an individual group's variability, wider variance would result in wider confidence intervals, making it more difficult to declare comparability.

This equivalence limit was computed as two times the upper 95% confidence limit of standard deviation estimate of the controlled dataset. For the case of cleaning experiments, equivalence limit was equal to 2 x [1.6 x 1.4] = 4.48, in which 1.6 was the standard deviation of a controlled data set (product A) and 1.4 was the multiplier for the 95% confidence limit of a standard deviation estimate, based on a sample size of 18.11 Using the upper confidence limit of the standard deviation estimate accounts for the uncertainty of such estimates based on a given sample size.


Figure 3
Therefore, the acceptance criterion for equivalency was that the upper and lower confidence limit of the difference between the two means should be within 4.48. The following two case studies show the application of this statistical approach to comparing the cleanability of different protein drug products.


blog comments powered by Disqus

ADVERTISEMENT

ADVERTISEMENT

FDA Approves Pfizer's Trumenba for the Prevention of Meningitis B
October 30, 2014
EMA: Extrapolation Across Indications for Biosimilars a Possibility
October 30, 2014
Bristol-Myers Squibb Announces Agreement to Acquire HER2-Targeted Cancer Treatment
October 29, 2014
Contract Research and Manufacturing Organization Paragon Bioservices Raises $13 Million
October 28, 2014
Yale and Gilead Extend Sequencing Initiative
October 28, 2014
Author Guidelines
Source: BioPharm International,
Click here