The ultimate goal of the filter sizing exercise is to quantify the effective filter area (EFA) needed to filter an entire production batch over a set time frame. Such testing typically is done using a flat disc with a diameter of 47-mm. The proper implementation of the flow decline method of assessing EFA requirements necessitates knowing the precise EFA of the model filter, which can be measured using staining techniques.

A filter-sizing study using a 47-mm flat disc is intended as indicator trial, which is preliminary to a more meaningful verification trial, or even to a more cogent assurance trial. The latter will require filter models characterized by a pleated membrane design. The EFA assessment of the pleated filter models can be performed with confidence. This will result in dependable projections of the EFA required for the batch processing filters.

Maik W. Jornitz is the group vice president of marketing & product management, filtration and fermentation technologies, and Wayne Garafola is an application specialist, both at Sartorius Stedim Biotech, Bohemia, NY, 631.870.8463,
Theodore H. Meltzer is the principal at Capitola Consulting Co., Bethesda, MD.

REFERENCES

1. Jornitz MW, Soelkner PG, Meltzer TH. Modern sterile filtration—the economics. PharmTech Eur. 2003;15(6)29–33.

2. Priebe PM, Jornitz MW, Meltzer TH. Making an informed membrane filter choice. BioProcess Int. 2003;1(10)64–6.

3. Parenteral Drug Association. Technical report 26: Liquid sterilizing filters. Bethesda, MD: PDA; 2008.

4. Meltzer TH, Jornitz MW. Pharmaceutical filtration—The management of organism removal. PDA, Bethesda, MD: PDA and River Grove, IL: DHI Publishing LLC; 2006.

5. Jornitz MW, Meltzer TH. Comparing flow rates of microporous membranes. Eur J Parenteral Pharm Sci. 2009:14(1)19–23.

6. Jornitz MW, Meltzer TH. Filtration and purification in the biopharmaceutical industry. New York, NY: Informa; 2008

7. Jornitz MW, Meltzer TH, Bromm H, Priebe PM. Testing for the optimal filter membrane. Gen Eng News. 2004;24(13)50–51.

8. Jornitz MW, Meltzer TH, Bromm H, Priebe PM. Choosing the appropriate membrane filter—test requirements. PDA J Pharm Sci Technol. 2005 Mar–Apr;59(2)96–101.

9. Jornitz MW. Filter construction and design. In: MW Jornitz, editor. Sterile Filtration. Berlin, Heidelberg: Springer Verlag; 2006. p. 105–124.


blog comments powered by Disqus

ADVERTISEMENT

Moscow Hosts IFPMA Biosimilars Conference
May 17, 2013
AbbVie and Alvine Will Collaborate on Celiac Disease Therapy
May 15, 2013
FDA Issues Pharmacoepidemiologic Safety Study Guidance
May 14, 2013
USP Launches Initiative to Fight Counterfeit Drugs in Sub-Saharan Africa
May 13, 2013
Amgen Forms New Joint Venture to Commercialize Vectibix in China
May 13, 2013
Upcoming Conferences
UPCOMING CONFERENCES

Access Programs for Investigational and Pre-Launch Drugs
Philadelphia, PA | July 17-18, 2013
Request Brochure

Strategic Pipeline Planning & Portfolio Valuation
Philadelphia, PA | August 13-14, 2013
Request Brochure

MES 2013 - Forum on Manufacturing Execution Systems
Philadelphia, PA | August 14-15, 2013
Request Brochure

Mobile Innovation for the Life Sciences Industry
Philadelphia, PA | August 20-21, 2013
Request Brochure

See All Conferences >>

ADVERTISEMENT

Author Guidelines
FindPharma
Source: BioPharm International,
Click here