Eden Biodesign Ltd.
Improving speed and quality, and reducing the cost of technology transfers is becoming increasingly important in the biopharmaceutical industry. Microbial fermentation processes have challenging equipment requirements, such as high heat and oxygen transfer rates, and ensuring minimal and consistent medium concentration changes resulting from condensate gain during steam-in-place and evaporative losses during media hold and fermentation. This article presents a platform approach to equipment characterization for microbial fermenters. These tests are used to gain understanding of the equipment capabilities before starting process runs. The platform presented here outlines a wet testing approach that has been successfully executed at pilot scale (300-L) for a dual-purpose reactor (used for both mammalian cell culture and microbial fermentation) and in a large-scale (10,000-L) fermenter. Comprehensive equipment characterization using a platform approach streamlines the technology transfer and maximizes success rates during process runs.

An optimized and fast-growing microbial culture is a dynamic process, and ensuring that the equipment is suitable for meeting these challenges is necessary for project success. These cultures tend to have a high oxygen demand that the fermenter must be able to meet to sustain cell growth and desired productivity. The culture also generates significant amounts of heat that the fermenter must remove to maintain temperature control. To ensure success during actual process runs, it is important to understand oxygen supply and heat removal capabilities before operating the process in the fermenter. Water-based tests were developed to characterize heat removal and oxygen supply capacity to understand if any equipment modifications would be required to meet process requirements. This testing should be performed early in technology transfer facility fit activities to allow time for equipment modifications, if needed.

Microbial media generally are batched into the fermenter and then steam sterilized-in-place (SIP). The SIP cycle is automated to ensure control within the required temperature range. Temperatures outside the acceptable range could result in insufficiently sterilized medium or overheated medium. Additionally, evaporation or condensation can occur during the SIP cycle. The change in fermenter weight should be characterized or eliminated during SIP operations to ensure the target medium concentration for optimal growth is achieved. After sterilization, the fermentation medium often is held at specified conditions until inoculation. Determining the evaporation rate during the medium hold is essential for achieving the correct medium concentration at the time of inoculation. To compensate for the evaporation rate, additional water can be added during media preparation, and adjustments to the air flow rate can be made to minimize evaporative losses. Water-based testing was developed to understand parameters around media SIP and hold conditions to ensure the target starting media concentration would be met.

Materials and Methods

Fermenter Characteristics


Table 1. Pilot- and large-scale fermenter characteristics. The agitation setting was scaled between the pilot- and large-scale fermenters by maintaining the ratio of agitator power draw (P) per unit volume (V).
Table 1 lists the fermenter dimensions and operational settings for both pilot and large scales.

Heat Removal Characterization




To maintain constant temperature control the fermenter must have sufficient heat removal capacity to remove metabolic heat generated by the cells and mechanical heat generated by the agitator. A common heat transfer scale-up challenge stems from the fact that the relative heat transfer area decreases with increasing fermenter scale. The heat transfer rate (HTR) can be calculated using a simple heat transfer equation:

in which m is the mass of water in the fermenter (kg), C p is the heat capacity of water at 37 C (4.181 kJ/kg/C),1 T is the temperature of water in the fermenter (C), t is time (h), and dT/dt is the rate of temperature change as the slope of water temperature versus time curve.

Strategies for maintaining temperature control involve equipment modifications such as: lowering chilled water or glycol temperature to increase the driving force for heat removal (dT/dt), ensuring jacket and coils have minimum resistance, and adding internal cooling coils to increase heat transfer surface area.

The fermenters were filled to different target weights and heated to approximately 75 C. The temperature set point was changed to 10 C, which resulted in a 100% cooling output on the temperature control loop. The rate of temperature change was estimated by the slope of the linear portion of the temperature-versus-time curve from 41 C to 34 C. This range encompasses the process temperature set point of 37 C. The HTR was then calculated using Equation 1.


blog comments powered by Disqus

ADVERTISEMENT

ADVERTISEMENT

EMA Warns of Falsified Herceptin Vials
April 16, 2014
Mallinckrodt to Acquire Questcor Pharmaceuticals
April 16, 2014
American CryoStem and Rutgers University File Joint Patent on Stem Cell Platform
April 11, 2014
Center for Biologics Evaluation and Research Relocates
April 11, 2014
PhRMA Report Reveals Growth Trajectories and Policy Factors Affecting Biopharmaceutical Growth
April 11, 2014
Author Guidelines
Source: BioPharm International Supplements,
Click here