Optimizing Drug Delivery for Modern Biologics - This article discusses potential opportunities to improve the patient experience through formulation and delivery device technologies. - BioPharm

ADVERTISEMENT

Optimizing Drug Delivery for Modern Biologics
This article discusses potential opportunities to improve the patient experience through formulation and delivery device technologies.


BioPharm International
Volume 25, Issue 5, pp. 30-32

For many of today's biologic drugs, formulation and delivery options can present multiple dilemmas when determining product attributes, including frequency of dosing, dose volume, number of treatments, and delivery mechanism. This article discusses potential opportunities to improve the patient exerperience through formulation and delivery device technologies.

In an ideal world, patients with chronic conditions could take a single pill once a year, or undergo a one-time noninvasive treatment that is administered without the need for a hospital or doctor visit. Unfortunately, treatment regimens for many of today's most prevalent chronic conditions, such as cancer, diabetes, and autoimmune diseases, require multiple, repeated doses of drug at frequent and regular intervals.

There are opportunities, however, to improve the patient experience using formulation and delivery device technologies. Treatment regimens can be optimized, for example, by: formulating drugs to higher concentrations to reduce dosing frequency; using higher-volume delivery systems to deliver a larger volume and reduce dosing frequency; and using higher-volume systems.

To give an example, monoclonal antibody (mAb) drug products have been approved for human therapeutic use for more than 20 years and affect a diverse range of therapeutics targets, including indications for prophylaxis of organ rejection following transplant, cancer, and various autoimmune diseases (e.g., rheumatoid arthritis, multiple sclerosis, Crohn's disease, and psoriasis). Most of these approved mAb products are intended for use in an acute care setting and must be administered through intravenous (IV) infusion. These accommodations are necessary because of the need for weight-based dosing of some products due to the potential for toxicity at higher doses; the potential for anaphylaxis or other adverse reaction; and the need for concurrent administration of other drugs intravenously, as with certain chemotherapeutic regimens.

There are, however, approved products intended for self-injection by patients, usually for autoimmune diseases like those previously mentioned. These include several TNF-α antibody products such as Johnson & Johnson's Simponi and Abbott Laboratories' Humira. These injections are typically designed for delivery into the subcutaneous space. Attributes of these products have allowed for self-administration, including a relatively low dose (< 100 mg) for efficacy and a reduced risk of life-threatening adverse reaction. Both Simponi and Humira are packaged in 1-mL in length prefilled syringes and dosed on a weekly, semi-monthly, or monthly basis, depending on the patient's particular indication.

In the case of most TNF-α therapies, the therapeutic target and properties of the antibodies used have allowed for relatively easy formulation and manufacturing because the final product viscosity is low (less than five centipoise) and because the product can be delivered through commonly available and well-characterized prefillable syringe systems. However, as pharmaceutical companies develop and test antibodies for new therapeutic products, often in the search for better efficacy and reduced side effects, challenges can arise. In cases where the dose required for efficacy is significantly higher than currently approved self-injected products, for example, one must choose between more frequent subcutaneous injections and clinically administered IV infusion.

Potential solutions would be to increase the dose concentration to fit within the classic 1-mL volume limitation, or to expand the dose to a larger volume. Concentration has apparently been the choice for many products to date because dosages have increased in the cases of products like Bristol-Myers Squibb's Orencia, although the 1-mL paradigm has not been broken. In fact, some recently introduced self-injected products, such as UCB's Cimzia, have concentrations of up to 200 mg/mL.

The exponential relationship between product concentration and viscosity, which often becomes readily apparent above 100 mg/mL, may limit this strategy significantly because the product either may not be deliverable by self-injection or may not be amenable to existing fill/finish processes if it is too viscous. Concentration to the necessary level in the final product may not be possible for all products, because in many cases, upstream purification and manufacturing processes may limit the maximum concentration for the final drug product more than delivery and fill/finish process concerns. Additionally, drug-product properties, such as pH and osmolality, along with the use of certain excipients, may limit the most appropriate drug-product concentration. These properties may need to be kept within certain ranges to prevent patient discomfort and site reaction upon injection. Certain emerging formulation technologies, including the use of nonaqueous solutions, have shown promise towards mitigating such concerns, but are awaiting regulatory approval.


blog comments powered by Disqus

ADVERTISEMENT

ADVERTISEMENT

Suppliers Seek to Boost Single-Use Technology
August 21, 2014
Bristol-Myers Squibb and Celgene Collaborate on Immunotherapy and Chemotherapy Combination Regimen
August 20, 2014
USP Center in Ghana Receives International Lab Accreditation
August 15, 2014
USP Awards Analytical Research
August 15, 2014
FDA Warns about Fraudulent Ebola Treatments
August 15, 2014
Author Guidelines
Source: BioPharm International,
Click here